Customization: | Available |
---|---|
Type: | Operation Area Sign, Parking Lift |
View Distance: | >800 M |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Name
|
Parking Boom Barrier
|
Voltage
|
220 ~ 240V
|
Power
|
90W
|
Arm length
|
1 ~ 6 meters
|
Arm Gate Material
|
Aluminum Alloy
|
Size of Housing
|
405 * 292 * 1019 mm
|
Housing Material
|
Galvanized Plate
|
Rail Lifting Time
|
6 seconds
|
Working Temperature
|
-25 °C ~ 80 °C
|
Working Humidity
|
5% ~ 95%
|
Warranty
|
1 Year
|
Power supply: 220VAC 50HZ / 110VAC 60HZ
Motor's power: 90W 220VAC
Max length of boom: 6m
Time for up/down: 3S( for 1~3m),6S( for 4~6m)
Environment temperature: -20oC-50oC
Protection class: IP55
Power supply: 220VAC 50HZ / 110VAC 60HZ
Motor's power: 80W 24VDC
Max length of boom: 6m
Time for up/down: 3S( for 1~3m),6S( for 4~6m)
Environment temperature: -20oC-50oC
Protection class: IP55
Number
|
Trouble
|
Cause
|
Shooting
|
1
|
Motor of Barrier does not work
|
1,No power supply
|
1,Check power supply
|
2,Break fuse
|
2,Change fuse
|
||
3,Motor is damaged
|
3,Change the motor
|
||
2
|
Barrier can open but can not close
|
1,Photocell is not connected properly
|
1,Connect the photocell
|
2,Photocell beam is block off
|
2,Clear out obstacle
|
||
3,Photocell is broken
|
3,Change a new device
|
||
3
|
Barrier can open (close) but can not close (open)
|
1,Position of limit switch is not correct
|
1,Adjust position
|
2,Limit switch is damaged
|
2,Change limit switch
|
||
4
|
Barrier can not locate accurately
|
1,Distance of limit switch is too large
|
1,Adjust position of limit switch
|
2,Limit switch is wrong
|
2,Change limit switch
|
||
3,Magnetic-stell's position is wrong
|
3,Re-adjust the position
|
||
5
|
Release device of Barrier is doesn't work
|
1,Operating handle is broken
|
1,Change the handle
|
2,Worm gears are jammed
|
2,Rotate the pinion
|
||
6
|
Push the "OPEN" button but the Barrier gate close
|
Whether "+MOTOR-" wires are connected wrong
|
Connect correctly according to wiring diagram
|
7
|
Motor of Barrier can work but boom can not work
|
Compression spring of clutch is dead
|
Change the spring
|